describe metrics formula with cavets description
hxr_750_ar_scf
Argon inventory inside subcooler HXR750 using the HXR dimensions/specs and PDT_751ALT
data. Estimate includes ONLY the liquid SCFs.
As part of the calculation PDT_751ALT
is converted from inches of H2O to inches of argon height.
hxr_750_ar_scf =
content of bottom head + tube volume + content of top head. The height of liquid in the tank based on PDT751ALT
. The pressure is PT601
.
site | shell ID | bottom | top | tube | tube ID | tube no. |
---|---|---|---|---|---|---|
All sites | 12.39 | 5.25 | 39 | 24 | 0.62 | 73 |