describe metrics formula with cavets description
hxr_750_ar_scfArgon inventory inside subcooler HXR750 using the HXR dimensions/specs and PDT_751ALT data. Estimate includes ONLY the liquid SCFs.
As part of the calculation PDT_751ALT is converted from inches of H2O to inches of argon height.
hxr_750_ar_scf = content of bottom head + tube volume + content of top head. The height of liquid in the tank based on PDT751ALT. The pressure is PT601.
| site | shell ID | bottom | top | tube | tube ID | tube no. |
|---|---|---|---|---|---|---|
| All sites | 12.39 | 5.25 | 39 | 24 | 0.62 | 73 |
github task #147 contains extra details on it