CARdata/MARS documentation

describe metrics formula with cavets description

View the Project on GitHub befinvestments/spine

pu930a_n2_dre

This new will calculate the removal efficiency of n2 contaminant by the PU930 Purifier beds. It is calculated based on the ratio of the outlet and inlet N2 ppm level.

formula

The primary logic for the beds

pu930a_n2_dre = (1 - (ppm out/ppm in))*100 when PU930AMODE_STATE == 1